This document outlines materials that are not accepted at Alter facilities and materials that may be accepted if certain conditions are met. This list is not intended to be comprehensive. Common sense and best judgment will be used to determine which materials can be managed in a safe and responsible manner that minimizes risk and potential liabilities for all parties. Special situations or requests for deviations are to be discussed and cleared with your account executive prior to delivery. Alter's account executives and facility managers are available to answer questions or to discuss concerns you may have. For complete information visit Alter Our Environment or watch our Inbound Material Source Control interactive presentation.
MATERIAL

AEROSOL CANS
  CONDITIONS FOR ACCEPTANCE

Empty and punctured or crushed.
AIRCRAFT MATERIAL   Verified free of radioactive sources and no aluminum/lithium alloys or chemical residues.
APPLIANCES, HOUSEHOLD
(refrigerators, dryers, microwaves, dehumidifiers, air conditioners, commercial coolers, dishwashers, furnaces, freezers, clothes washers, hot water heaters, kitches ranges/ovens, thermostats, drinking fountains, fluorescent lights, trash compactors, vending machines, etc.)
  Iowa facilities may accept demanufactured appliances from certified demanufacturers only or may accept if facility is certified to demanufacture (may be subject to fee).

Facilities outside of Iowa may accept if certified free of refrigerants or if facility has the equipment to recover refrigerants. White goods must also be free of PCB-containing small capacitors and ballasts, and mercury-containing components (bulbs, switches), or be removed by the accepting facility.

No sodium chromate, ammonia, or asbestos containing appliances.
ASBESTOS-CONTAINING SCRAP
(furnaces, pipes, building materials, etc.)
  Asbestos removed in accordance with applicable regulations.
BALLASTS   If labeled "No PCBs" or documentation (i.e., analytical test results) supporting less than 50 ppm PCB concentrations, or if no label or documentation, select facilities may accept if attached to a household appliance and facility has demanufacturing capabilities.
BARRELS, DRUMS, AND OTHER
CONTAINERS
  Empty, open to allow inspection, bearing no hazard or warning labels or placards that are not covered with a "Certified Clean" or equivalent decal, and containing no non-metal residual materials or fluids.
BATTERIES, LEAD-ACID ONLY   Select facilities may accept lead-acide (car, industrial) if segregated; no "universal waste" batteries (e.g. NIMH, NiCd, lithium or Absolyte).
BERYLLIUM OR MATERIALS
CONTAINING BERYLLIUM
  None
CAPACITORS   If labeled "No PCBs" or documentation (i.e., analytical test results) supporting less than 50 ppm PCB concentrations, or if no label or documentation, select facilities may accept if attached to a household appliance and facility has demanufacturing capabilities.
COMPRESSED/LIQUEFIED GAS CYLINDERS AND VESSELS
(oxygen, propane, acetylene, argon, refrigerants, fire extinguishers, etc.)
  Segregated, valves removed, depressurized, and rendered unusable.
DROSS, METALLIC   Certification and documentation that the dross is not hazardous and has been managed in compliance with applicable legal requirements
ELECTRONIC SCRAP
(VCRs, radios, office equipment, copy machines, computers, keyboards, CPUs, printers, circuit boards, other peripherals, etc.)
  Electronics without circuit boards or cathode ray tubes (monitors, televisions) are acceptable.

If segregated from other scrap, select facilities may accept electronics with circuit boards and cathode ray tubes.
GAUGES AND MEASURING DEVICES   Verified free of radioactive sources.
HEATERS, OIL-FILLED SPACE/PORTABLE, PRE-1980   Documentation supporting that oil did not contain greater than 50 ppm PCBs and drained of free-flowing oil.
HYDRAULIC EQUIPMENT, PRE-1980 OR INDETERMINABLE   Documentation supporting that oil did not contain greater than 50 ppm PCBs and drained of free-flowing oil (or equipment was decontaminated in accordance with federal TSCA regulations).
LEAD-PAINTED SCRAP   Select facilities may accept if identified and segregated during unloading.
LIGHTING FIXTURES, OUTDOOR AND INDUSTRIAL/COMMERCIAL
(sodium/mercury vapor, metal halide, fluorescent, neon)
  Free of capacitors or ballasts with PCB concentrations greater than 50 ppm and free of bulbs

Select facilities may accept household fixtures.
See APPLIANCES
MAGNESIUM TURNINGS   None
MILITARY AND GOVERNMENT SCRAP   Certification statement stating scrap to be free of explosive, radioactive, and hazardous materials.
NATURAL GAS PIPELINE SYSTEM COMPONENTS   Documentation obtained in accordance with TSCA regulations supporting that PCB concentrations are less than 50 ppm.
PAINT CANS   Open, empty and dry.
PUMPS, PRE-1980 OR INDETERMINABLE (sump, well, etc.)   Documentation supporting that oil did not contain greater than 50 ppm PCBs and drained of free-flowing oil (or equipment was decontaminated in accordance with federal TSCA regulations with Environmental Manager approval) and free of mercury-containing devices
RADIOACTIVE SOURCES
(gauges and measuring devices using radioactive source material, medical equipment containing a radioactive source, cameras containing a radioactive source, underground pipe, etc.)
  None
REFRIGERANT-CONTAINING SCRAP
(refrigerators, heat pumps, motor vehicle air conditioners, window and terminal air con-ditioners, water coolers, dehumidifiers, etc.)
  Certification upon delivery or prior to shipment that refrigerant has been removed or leaked prior to shipment, or

Select facilities may accept in select situations for a fee if facilities exist to recover refrigerant
SCRAP CONTAINING EXCESSIVE TRASH OR NON-METALLIC RECYCLABLES   None
SCRAP CONTAINING FLUIDS (oil, fuel, coolant, antifreeze, cutting oil, hydraulic oil, solvents, etc.)   All fluids to be drained prior to delivery. See also AEROSOL CANS, BARRELS/DRUMS, HEATERS, HYDRAULIC EQUIPMENT, PAINT CANS, PUMPS, TANKS, and VEHICLES.
SHELLS, MUNITIONS
(brass shells, munitions casings, etc.)
  Segregated from other commodities and discharged or otherwise spent
TANKS, ABOVEGROUND AND UNDERGROUND STORAGE
(mobile, portable, fixed)
  A minimum of 3-foot square hole at both ends and thoroughly cleaned of liquids and gases (odor free).
TIRES   Select facilities may accept if attached to an auto body; a deduction may be applied.
TRANSFORMERS   Dry type or Documentation supporting that oil did not contain greater than 50 ppm PCBs and drained of free-flowing oil (or equipment was decontaminated in accordance with federal TSCA regulations).
USED OIL FILTERS   Select facilities may accept if hot-drained of free-flowing oil for a minimum of 24 hours, punctured and containerized when delivered.
VEHICLES
(crushed, whole or parts including motors, transmissions, and fuel tanks)
  Free of mercury switches, batteries, refrigerants, antifreeze, fuel, and oils. Refrigerant recovery certification required from supplier.

Select facilities may accept "as is" if uncrushed and facility is equipped to demanufacture.
WASTE, HAZARDOUS OR TOXIC
(as defined by Federal, State, or Local regulations)
  None
WHITE GOODS   See APPLIANCES.
WIRE/CABLE   Free of asbestos and/or PCBs